TestLab | Testing House, Test Equipment Rental, Service, Calibration, ...



WKL 100/40 - Weiss Climate chamber
Type: WKL 100/40
Test space contents (Litre): 100
Test space dimensions
Height approx. (mm): 500
Width approx. (mm): 490
Depth approx. (mm): 400
Outside dimensions
Height approx. (mm): 1190
Width approx. (mm): 780
Depth approx. (mm): 1105
Temperature changing rate cooling (K/min): 5.0
Temperature changing rate heating (K/min): 3.5
Temperature changing rate linear (K/min): -
Humidity range (% r.h.): 10 to 98
Maximum heat compesation (W): 1100
Humidity constancy in time (% r.h.): ±0.5 to ±2.0
Temperature constancy in time (K): ±0.3 to ±0.5
Temperature homogeneity in space (K): ±0.5 to ±1.5
Calibration values (°C): +23°C / 50% r.h. and +95°C/ 50 % r.h.
Condenser: air-cooled
Chamber weight in kg (approx.): 190